					Overload Protector Load Cells 
					
					The Lebow Load Cell Overload 
					Protector is available in sizes that will accommodate load 
					cells with capacities up to 3,000 lbs. and overloads to 
					15,000 lbs. in tension and 20,000 lbs. compression. 
					 
					The Lebow Load Cell Overload Protector is available with an 
					optional end plate assembly and rod ends. The Overload 
					Protector eliminates downtime and replacement costs due to 
					damaged strain gage load cells. The unit does not 
					appreciably affect the cell’s dynamic response. Up to its 
					set point (usually 110%), the application of load results in 
					linear deflection of the system. At 110% of rated load, the 
					patented non-linear spring supporting the cell abruptly 
					collapses, shunting the load in excess of 110% to the 
					built-in mechanical stops. 
					 
					When the load is removed, the springs automatically return 
					to their original position. The low spring rate, above rated 
					load, allows wide tolerances in mechanical stop settings. 
					 
  
					
  |